ISO fittings carry the elastomer-sealed system into the large bores: the same centering ring and O-ring principle as KF, scaled up to ISO63 to ISO500. What changes is the closure — and that is the first thing to specify.
PC Vacuum supplies both closure styles and the full fitting range around them.
- The elastomer-sealed system scaled to large bores: catalog coverage ISO63 to ISO500.
- Two closure styles — ISO-K claw clamps and ISO-F bolted outer rings — supplied with the full fitting range.
- Fittings include weld flanges, blanks, straight tubes, elbows, tees, manifolds and bellows.
- Claw calipers in stainless steel and aluminium, with the recommended clamp count per size given in the catalog tables.
Why Choose PC Vacuum ISO Vacuum Fittings
- ISO 9001 quality system. The company is certified to the ISO 9001 quality management system and holds self-developed patents, as stated in the company catalog.
- In-house precision machining. Dozens of machining centres covering 2-axis to 5-axis work support both catalog parts and prototype customization.
- Catalog-listed inspection steps. Spectral analysis, dimension and height measurement, surface-roughness measurement, concentricity checks, helium mass-spectrometer leak testing and ultrasonic cleaning are part of the company’s stated process flow.
- Traceable production management. ERP and MES systems support a standardized, digitally traceable flow from material entry through to packing.
ISO-K or ISO-F: specify the closure
- ISO-K — closed with claw clamps (single-claw, double-claw or claw-chain). Fast to open and close; needs clearance around the flange for the claws.
- ISO-F — closed with bolts through the flange’s outer ring. Used where a defined bolted joint is required or space does not allow claws.
Both styles mate to the same centering ring and O-ring hardware; components are confirmed by size, not by the ISO letter alone.
The two closures are compared in detail — outer diameters at the same nominal size, clamp counts and bolt hole patterns — in ISO-K vs ISO-F Vacuum Flanges.
If the flange in front of you is unmarked and neither closure is obvious, the size band, sealing element and closing hardware are the three checks that settle it — see How to Identify a Vacuum Flange: KF, ISO and CF at a Glance.
The ISO range at a glance
ISO-K Weld Flange
ISO-K Blank Flange
ISO-F Rotatable Flange
ISO-K Straight Tube Fitting
ISO-K 90 Degree Elbow
ISO-K Tee
ISO-K Cross
ISO-K Vacuum Bellows
| Product | Coverage | Notes |
|---|---|---|
| ISO-K Weld Flanges | ISO63 – ISO500 | Internal weld |
| ISO-K Blank Flanges | ISO63 – ISO500 | — |
| ISO-F Rotatable Flanges | ISO63 – ISO500 | Bolted outer ring, 4-Φ9 to 16-Φ14 |
| ISO-K Straight Tubes | ISO63 – ISO500 | L per size table; length to requirement |
| ISO-K 90° Elbows | ISO63 – ISO250 | L = 88–208 |
| ISO-K Tees | ISO63 – ISO250 | L1/L2 per size table |
| ISO-K Manifolds / Crosses | ISO63 – ISO250 | Four-port manifold |
| ISO-K Bellows | ISO63 – ISO500 | L = 100–2000 mm; custom lengths; end flanges listed separately |
| ISO Clamps (claw calipers) | ISO63 – ISO500 | Stainless calipers; aluminum single/double claw, quantity per size |
| Seals | KF10 – ISO250 | Centering rings, O-rings, outer rings — see Vacuum Seals and Clamps |
| ISO-K Pneumatic Angle Valves | ISO63 – ISO320 | See Vacuum Valves |
Hardware for the Large-Bore Joint
An ISO joint needs its sealing set and its closing hardware to match the flange size. The range lists both alongside the fittings, so the whole joint is specified from one place.
Sealing set per size
Centering rings, O-rings and aluminium outer rings cover the ISO sizes; the assembly is ordered by flange outer diameter rather than by nominal size alone.
Claw or bolt closure
ISO-K claw calipers and ISO-F bolted rings cover the same sizes, so the closure follows the installation space instead of limiting it.
Fittings matched to the closure
Weld flanges, blanks, tubes and bellows are listed per ISO-K / ISO-F style, keeping the whole joint consistent by size and closure.
Applications of ISO Vacuum Fittings
The company catalog lists the following fields of use.
Semiconductor manufacturing
Process tools, load locks and forelines put the connection where it is broken most often — pump inlets, gauge ports and service points.
Liquid cooling technology
Coolant loops and distribution units need connections that can be reconfigured between builds without re-welding the line.
Energy and batteries
Vacuum drying, filling and leak-check stations rely on joints that open for maintenance and reseal the same way.
Life sciences
Laboratory vacuum lines and analytical instruments use tool-free assembly and a seal that repeats across rebuilds.
Aerospace
Test benches and environmental chambers run their roughing and intermediate lines through the same standard hardware.
Research institutes
Experimental rigs are rebuilt frequently; standard components let the piping be re-routed and re-sized instead of replaced.
Fields of use as listed in the company catalog. The connection size, seal material and line layout for a specific system are confirmed in the quotation.
Frequently asked questions
What is the difference between ISO-K and ISO-F?
ISO-K closes with claw clamps and opens quickly; ISO-F closes with bolts and suits installations that need a bolted joint or lack claw clearance. Both use the same centering ring and O-ring sealing set for a given size.
Which clamps fit ISO-K flanges?
Stainless steel claw calipers cover ISO63 to ISO500 with M8/M10/M12 bolts; aluminum single-claw and double-claw (bilateral) calipers are sized by bolt specification, with the recommended clamp count per flange size given in the catalog tables. Match the clamp to the flange outer diameter and claw groove.
RFQ checklist
Send: ISO size(s) · ISO-K or ISO-F per end · configuration (flange, tube, elbow, tee, manifold, bellows) · material and O-ring requirement · medium, vacuum level and temperature · quantity · drawings.
Certifications and Quality Documents
Certificate images and quality documents are added here once the release-ready files are confirmed by the company; the outlines below mark the positions in the layout.
Quality management
Product certification
Test & inspection records
Request an ISO Vacuum Fittings Quotation
Send the ISO size, ISO-K or ISO-F per end, the configuration and any O-ring requirement, and the quotation is prepared from those inputs. A drawing is enough to start.