Product photo and dimensional drawing — click a thumbnail to switch.
The GD-J series manual high vacuum angle valve opens and closes a high-vacuum line by hand: rotating the handle drives a screw that lifts the valve plate. The design pairs a corrugated-tube shaft seal with a stainless steel body, forged and welded, for stable operation on air and non-corrosive gas duties. The catalog covers KF16 to KF50 (models GD-JB16KF – GD-JB50KF).
- Catalog sizes: KF16 · KF25 · KF40 · KF50
- Custom sizes, materials and cleaning/packing handled through Custom Manufacturing
Why Source KF Manual High Vacuum Angle Valve from PC Vacuum
- ISO 9001 quality system. The company is certified to the ISO 9001 quality management system and holds independent R&D patents, as stated in the company catalog.
- Precision machining capacity. Dozens of machining centers cover 2-axis to 5-axis work, supporting both standard parts and prototype customization.
- Catalog-listed inspection processes. Spectral analysis, dimension and height measurement, surface-roughness measurement, concentricity checks, helium mass-spectrometer leak testing and ultrasonic cleaning are part of the company’s stated process flow.
- Traceable production management. ERP and MES systems support standardized, digitally traceable production from material entry to packing.
Size Range
KF16
Compact sizes for laboratory and pilot vacuum lines, pump connections and maintenance loops. Sizes covered: KF16.
KF25
Mid-range sizes for manifold branches, chamber ports and distribution lines between pumps and vessels. Sizes covered: KF25.
KF40 – KF50
Large sizes for chamber outlets and high-flow sections; confirm mating interfaces against the drawing before ordering. Sizes covered: KF40 · KF50.
Key Features
Isolation in the line
Valves cut a vacuum line or chamber port off from the pump side without breaking down the rest of the system.
Manual and pneumatic operation
Manual valves suit setup and maintenance points; pneumatic valves integrate into automated sequences.
Standard interfaces
Valve bodies carry KF, CF or ISO connections, so the valve drops into the same hardware family as the line.
Body and seal materials
The catalog lists stainless steel bodies; seal materials are confirmed at quotation against the medium.
Angle and ball formats
Angle valves suit pump-line geometry; ball valves give a full-open path for foreline and vent duties.
Actuation ready
Pneumatic versions pair with your solenoid-valve and control scheme; electrical interface is confirmed at quotation.
Customization Options
Beyond the catalog sizes, KF Manual High Vacuum Angle Valve can be customized around your project requirements: non-standard dimensions, material selection, special cleaning and packing needs, and matching interface drawings. Send your drawing or working conditions, and the engineering team will confirm feasibility and applicability before quotation.
Discuss Your Custom Requirement
Production and Inspection
The company states in its catalog that production runs on dozens of CNC machining centers (2-axis to 5-axis) under an ISO 9001-certified quality management system, with ERP and MES supporting standardized, traceable workflows. Catalog-listed quality processes include spectral analysis of incoming material, dimension and height measurement, surface-roughness measurement, concentricity detection, helium mass-spectrometer leak testing, ultrasonic cleaning and protective packing before delivery. Applicable limits for your specific part are confirmed per working conditions during quotation.
Applications and Boundaries
Catalog context: high-vacuum line isolation on KF-sized ports — pump isolation, chamber branch shut-off. Naming note: the catalog English name is “Baffle Valve”; the page uses “angle valve” per trade usage — both refer to PC-050.
Applicability to your vacuum level, temperature and media is confirmed per working conditions before quotation.
The choice between this screw-driven valve and the pneumatic GDQ-J equivalent, with the utilities and mounting rules for each, is covered in Manual vs Pneumatic High-Vacuum Valves.
Options at a Glance
| Select | Options |
|---|---|
| Size | KF16 · KF25 · KF40 · KF50 |
| Model series | GD-J (manual, screw-driven) |
| Installation | Any direction |
Specification
| Model | ∅A (mm) | ∅B (mm) | C (mm) | L (mm) |
|---|---|---|---|---|
| GD-JB16KF | 30 | 17.2 | 60 | 40 |
| GD-JB25KF | 40 | 26.2 | 60 | 50 |
| GD-JB40KF | 55 | 41.2 | 78 | 65 |
| GD-JB50KF | 75 | 52.2 | 88 | 70 |
— transcribed from the catalog table; re-checked against the drawing before order confirmation.
Values are transcribed from the catalog tables and re-checked against the drawings before order confirmation.
How to Select
- Match the KF size; check height C and length L against the installation.
- Manual suits lines operated by hand at the panel; for remote/automated control use the pneumatic series — see KF Pneumatic High Vacuum Angle Valve.
- State the medium and vacuum level in the RFQ to confirm seal materials.
Compatible Components
KF Pneumatic High Vacuum Angle Valves · KF Manual Ball Valves · KF clamps · Centering rings and O-rings · Vacuum Vent Valve
How the Valve Sits in a Line
A vacuum valve is specified by its connection standard on each port and by how it closes: a ball valve rotates a bore through the seat for a full-open path, while an angle valve lifts a plate against a seat at right angles to the flow. The valve ports connect with the same clamps, bolts and gaskets as the matching flanges, so the valve is treated as one more component in the joint chain — select it by port standard and size, then by operating method.
Installation Notes
- Orientation: mount the valve so the flow direction and actuator movement match the manufacturer’s marking and your layout.
- Connections: build each port joint per its standard — clamp and centering ring for KF/ISO ports, bolts and gasket for CF ports.
- Actuation: for pneumatic valves, plan the air supply and solenoid control with your control scheme before installation.
- After installation: exercise the valve and evaluate the joints as part of your system’s standard leak-check procedure.
For system-specific welding and leak-test requirements, confirm with your process specification; our engineers can advise during quotation.
Frequently Asked Questions
Angle valve or baffle valve?
Same product — the catalog prints “baffle valve”, the trade also says “angle valve” for the right-angle body.
Why a corrugated-tube shaft seal?
It seals the stem without sliding elastomer contact, supporting reliable closing over repeated cycles.
Can I automate it later?
The GDQ-J pneumatic series covers automated duty; conversion of a manual body is confirmed at quotation.
RFQ Checklist
Send: KF size · model (GD-JB□□KF) · quantity · medium and vacuum level · temperature duty · installation orientation · drawings.
Customer Reviews
“We ordered parts for our test-stand vacuum lines. Dimension checks on arrival matched the catalog drawings, and assembly on site was straightforward.”
— T., Equipment Engineer
“Communication was clear through the RFQ stage: they asked for our dimensions and working conditions before quoting, and the parts matched what we agreed.”
— S., Procurement
“Consistent machining quality between batches. We use these parts on maintenance loops where the joints are opened regularly, and the sealing surfaces have held up well.”
— M., Maintenance Lead
Reviews shown are sample summaries pending verified customer feedback.
Certifications
ISO 9001 Quality Management System
Science & Technology SME Certificate
Patents & Design Certificates
Certificates as displayed in the company catalog; certificate documents are available on request.