Product photo and dimensional drawing — click a thumbnail to switch.
The CF-CF conversion flange steps between two CF sizes inside the metal-sealed system: knife-edge sealing on both sides, each closed over its own oxygen-free copper gasket. The catalog lists nine size pairs from CF25-CF16 to CF250-CF200, all with L = 76.2 mm.
- Stainless steel (grade confirmed at quotation)
- Custom sizes, materials and cleaning/packing handled through Custom Manufacturing
Why Source CF to CF Reducer Adapter from PC Vacuum
- ISO 9001 quality system. The company is certified to the ISO 9001 quality management system and holds independent R&D patents, as stated in the company catalog.
- Precision machining capacity. Dozens of machining centers cover 2-axis to 5-axis work, supporting both standard parts and prototype customization.
- Catalog-listed inspection processes. Spectral analysis, dimension and height measurement, surface-roughness measurement, concentricity checks, helium mass-spectrometer leak testing and ultrasonic cleaning are part of the company’s stated process flow.
- Traceable production management. ERP and MES systems support standardized, digitally traceable production from material entry to packing.
Key Features
Standards in one part
Each adapter joins two different connection standards, so clamp-type, bolted and sanitary lines can be mixed without custom machining.
Both ends specified independently
Order by the two end sizes; the catalog tables list each end’s dimensions separately.
Reducer and transition styles
Conical and straight reducing options cover size steps within the same standard as well as transitions between standards.
Machined from solid
Adapters are machined so that both sealing interfaces keep their standard geometry and finish.
Material options
The catalog lists stainless steel for this series; the specific grade is confirmed at quotation.
System compatibility
Bridges KF, ISO, CF and sanitary lines; pair each end with its own clamps, bolts or gaskets.
Customization Options
Beyond the catalog sizes, CF to CF Reducer Adapter can be customized around your project requirements: non-standard dimensions, material selection, special cleaning and packing needs, and matching interface drawings. Send your drawing or working conditions, and the engineering team will confirm feasibility and applicability before quotation.
Discuss Your Custom Requirement
Production and Inspection
The company states in its catalog that production runs on dozens of CNC machining centers (2-axis to 5-axis) under an ISO 9001-certified quality management system, with ERP and MES supporting standardized, traceable workflows. Catalog-listed quality processes include spectral analysis of incoming material, dimension and height measurement, surface-roughness measurement, concentricity detection, helium mass-spectrometer leak testing, ultrasonic cleaning and protective packing before delivery. Applicable limits for your specific part are confirmed per working conditions during quotation.
Applications and Boundaries
Catalog context: stepping between CF sizes in UHV/high-vacuum manifolds while keeping the all-metal seal path continuous. Both joints are metal-sealed, so the seal character is preserved across the size change.
Applicability to your vacuum level, temperature and media is confirmed per working conditions before quotation.
Options at a Glance
| Select | Options |
|---|---|
| Large end | CF25 · CF35 · CF50 · CF63 · CF80 · CF100 · CF150 · CF200 · CF250 |
| Small end | One size down per table (e.g. CF63-CF50, CF100-CF80) |
| Material | Stainless steel (grade confirmed at quotation) |
Specification
| Model | ∅A (mm) | ∅B (mm) | E (mm) | F (mm) | L (mm) |
|---|---|---|---|---|---|
| CF25-CF16 | 54 | 34 | 10.5 | 7.3 | 76.2 |
| CF35-CF25 | 70 | 54 | 13 | 10.5 | 76.2 |
| CF50-CF35 | 86 | 70 | 16 | 13 | 76.2 |
| CF63-CF50 | 114 | 86 | 17 | 16 | 76.2 |
| CF80-CF63 | 130 | 114 | 18 | 17 | 76.2 |
| CF100-CF80 | 152 | 130 | 20 | 18 | 76.2 |
| CF150-CF100 | 202 | 152 | 24 | 20 | 76.2 |
| CF200-CF150 | 253 | 202 | 24.5 | 24 | 76.2 |
| CF250-CF200 | 305 | 253 | 26 | 24.5 | 76.2 |
— A/B are the large/small flange outer diameters; E/F are the corresponding flange thickness values per the drawing.
Values are transcribed from the catalog tables and re-checked against the drawings before order confirmation.
How to Select
- Read the model as large CF-small CF; each side takes its own copper gasket.
- Confirm both bolt patterns against the CF flange table for the two sizes.
- Copper gaskets are replaced at each reassembly — order per size.
Compatible Components
CF Copper Gaskets · CF weld flanges · KF to CF Adapters · CF tubes and fittings
How Adapters Fit Into a System
An adapter is specified end by end: each end follows the dimensions of its own standard, and the sealing method of that standard applies on that side. A KF-to-ISO adapter, for example, closes with a KF clamp on one end and ISO claw clamps on the other, each with its own centering ring and O-ring. Sizing the adapter is therefore a matter of listing both end standards and sizes, then pairing each end with the hardware it would need if it were a plain flange of that type.
Installation Notes
- Identify both ends: confirm the standard, size and sealing hardware required on each side before ordering.
- Assembly: build each joint per its own standard — clamp, centering ring and O-ring for clamp-type ends; bolts and gasket for metal-seal ends.
- Alignment: support the adapter so neither joint carries bending load from the line.
- After assembly: evaluate the joints as part of your system’s standard leak-check procedure before putting the line into service.
For system-specific welding and leak-test requirements, confirm with your process specification; our engineers can advise during quotation.
Frequently Asked Questions
Does the all-metal seal survive the size change?
Yes — both sides close knife-edge over copper gaskets; the reducing body does not introduce an elastomer joint.
Why is L = 76.2 mm on every pair?
It is the fixed conversion-flange length in the catalog, independent of the size pair.
Are one-step pairs only, or any combination?
The catalog lists adjacent-step pairs; other combinations are confirmed at quotation.
RFQ Checklist
Send: both CF sizes · quantity · material · gasket quantities · medium and vacuum level · bake requirement if any · drawings.
Customer Reviews
“We ordered parts for our test-stand vacuum lines. Dimension checks on arrival matched the catalog drawings, and assembly on site was straightforward.”
— T., Equipment Engineer
“Communication was clear through the RFQ stage: they asked for our dimensions and working conditions before quoting, and the parts matched what we agreed.”
— S., Procurement
“Consistent machining quality between batches. We use these parts on maintenance loops where the joints are opened regularly, and the sealing surfaces have held up well.”
— M., Maintenance Lead
Reviews shown are sample summaries pending verified customer feedback.
Certifications
ISO 9001 Quality Management System
Science & Technology SME Certificate
Patents & Design Certificates
Certificates as displayed in the company catalog; certificate documents are available on request.