KF Pneumatic High Vacuum Angle Valve

KF High Vacuum Pneumatic Angle ValveKF High Vacuum Pneumatic Angle Valve — dimensional drawing

Product photo and dimensional drawing — click a thumbnail to switch.

The GDQ-J series pneumatic high vacuum angle valve opens and closes remotely: an electromagnetic directional valve steers compressed air to a cylinder that drives the valve plate. The same corrugated-tube shaft seal and stainless forged-and-welded body as the manual series, with optional magnetic position indication for open/closed feedback. The catalog covers KF16 to KF50 (models GDQ-JB16KF – GDQ-JB50KF).

  • Catalog sizes: KF16 · KF25 · KF40 · KF50
  • Custom sizes, materials and cleaning/packing handled through Custom Manufacturing

Get a Quotation

Why Source KF Pneumatic High Vacuum Angle Valve from PC Vacuum

  • ISO 9001 quality system. The company is certified to the ISO 9001 quality management system and holds independent R&D patents, as stated in the company catalog.
  • Precision machining capacity. Dozens of machining centers cover 2-axis to 5-axis work, supporting both standard parts and prototype customization.
  • Catalog-listed inspection processes. Spectral analysis, dimension and height measurement, surface-roughness measurement, concentricity checks, helium mass-spectrometer leak testing and ultrasonic cleaning are part of the company’s stated process flow.
  • Traceable production management. ERP and MES systems support standardized, digitally traceable production from material entry to packing.

Send Inquiry Now

Size Range

KF16

Compact sizes for laboratory and pilot vacuum lines, pump connections and maintenance loops. Sizes covered: KF16.

KF25

Mid-range sizes for manifold branches, chamber ports and distribution lines between pumps and vessels. Sizes covered: KF25.

KF40 – KF50

Large sizes for chamber outlets and high-flow sections; confirm mating interfaces against the drawing before ordering. Sizes covered: KF40 · KF50.

Key Features

Isolation in the line

Valves cut a vacuum line or chamber port off from the pump side without breaking down the rest of the system.

Manual and pneumatic operation

Manual valves suit setup and maintenance points; pneumatic valves integrate into automated sequences.

Standard interfaces

Valve bodies carry KF, CF or ISO connections, so the valve drops into the same hardware family as the line.

Body and seal materials

The catalog lists stainless steel bodies; seal materials are confirmed at quotation against the medium.

Angle and ball formats

Angle valves suit pump-line geometry; ball valves give a full-open path for foreline and vent duties.

Actuation ready

Pneumatic versions pair with your solenoid-valve and control scheme; electrical interface is confirmed at quotation.

Customization Options

Beyond the catalog sizes, KF Pneumatic High Vacuum Angle Valve can be customized around your project requirements: non-standard dimensions, material selection, special cleaning and packing needs, and matching interface drawings. Send your drawing or working conditions, and the engineering team will confirm feasibility and applicability before quotation.

Discuss Your Custom Requirement

Production and Inspection

The company states in its catalog that production runs on dozens of CNC machining centers (2-axis to 5-axis) under an ISO 9001-certified quality management system, with ERP and MES supporting standardized, traceable workflows. Catalog-listed quality processes include spectral analysis of incoming material, dimension and height measurement, surface-roughness measurement, concentricity detection, helium mass-spectrometer leak testing, ultrasonic cleaning and protective packing before delivery. Applicable limits for your specific part are confirmed per working conditions during quotation.

Send Your Inquiry

Applications and Boundaries

Catalog context: remote isolation of KF lines in automated systems — interlocks, pump sequences, process control. Actuation speed and control integration are confirmed per installation.

Applicability to your vacuum level, temperature and media is confirmed per working conditions before quotation.

What the pneumatic series requires at the installation — air supply, solenoid voltage and position feedback — is set out in Manual vs Pneumatic High-Vacuum Valves.

Options at a Glance

SelectOptions
SizeKF16 · KF25 · KF40 · KF50
Model seriesGDQ-J (pneumatic)
Air supply0.4–0.6 MPa
PowerAC220V 50Hz · AC110V or DC24V optional
Position indicationMagnetic switch, optional

Specification

Model∅A (mm)∅B (mm)C (mm)L (mm)
GDQ-JB16KF3017.26040
GDQ-JB25KF4026.26050
GDQ-JB40KF5541.27865
GDQ-JB50KF7552.28870

— A/B/C match the manual GD-J series of the same size; overall height differs with the cylinder. Dimensions for the actuated assembly are re-checked against the drawing before order confirmation.

Values are transcribed from the catalog tables and re-checked against the drawings before order confirmation.

How to Select

  1. Match the KF size; confirm air supply and voltage available at the installation.
  2. Choose position feedback where the control system needs open/closed confirmation — order the magnetic switch option.
  3. For manual panels, the GD-J series avoids the air supply dependency.

Compatible Components

KF Manual High Vacuum Angle Valves · CF Pneumatic High Vacuum Angle Valves · KF clamps · Centering rings and O-rings

How the Valve Sits in a Line

A vacuum valve is specified by its connection standard on each port and by how it closes: a ball valve rotates a bore through the seat for a full-open path, while an angle valve lifts a plate against a seat at right angles to the flow. The valve ports connect with the same clamps, bolts and gaskets as the matching flanges, so the valve is treated as one more component in the joint chain — select it by port standard and size, then by operating method.

Installation Notes

  • Orientation: mount the valve so the flow direction and actuator movement match the manufacturer’s marking and your layout.
  • Connections: build each port joint per its standard — clamp and centering ring for KF/ISO ports, bolts and gasket for CF ports.
  • Actuation: for pneumatic valves, plan the air supply and solenoid control with your control scheme before installation.
  • After installation: exercise the valve and evaluate the joints as part of your system’s standard leak-check procedure.

For system-specific welding and leak-test requirements, confirm with your process specification; our engineers can advise during quotation.

Frequently Asked Questions

What air supply does it need?

0.4–0.6 MPa compressed air, per the catalog.

Can I get open/closed feedback?

Yes — the optional magnetic switch provides position indication.

Does the valve fail open or closed?

Fail position depends on the control scheme — specify the requirement in the RFQ.

RFQ Checklist

Send: KF size · model (GDQ-JB□□KF) · quantity · air supply and voltage available · position feedback requirement · medium and vacuum level · drawings.

Request a quotation

Request a Quotation

Customer Reviews

“We ordered parts for our test-stand vacuum lines. Dimension checks on arrival matched the catalog drawings, and assembly on site was straightforward.”

— T., Equipment Engineer

“Communication was clear through the RFQ stage: they asked for our dimensions and working conditions before quoting, and the parts matched what we agreed.”

— S., Procurement

“Consistent machining quality between batches. We use these parts on maintenance loops where the joints are opened regularly, and the sealing surfaces have held up well.”

— M., Maintenance Lead

Reviews shown are sample summaries pending verified customer feedback.

Certifications

Certificate image

ISO 9001 Quality Management System

Certificate image

Science & Technology SME Certificate

Certificate image

Patents & Design Certificates

Certificates as displayed in the company catalog; certificate documents are available on request.

Request a Quotation

Send your sizes and working conditions — our engineers will confirm material, dimensions and applicability before quotation.