ISO-K vs ISO-F Vacuum Flanges: Clamps, Bolts and Installation Space

Quick answer. ISO-K and ISO-F are two ways of closing the same large-bore ISO joint. Both use a centering ring and an O-ring between the flange faces — the sealing hardware is identical for a given nominal size. What changes is the last step: ISO-K closes with claw clamps, and ISO-F closes with bolts through an outer ring that turns on the stub. The practical consequence is a layout one, not a sealing one — the ISO-F outer diameter is larger than the ISO-K flange of the same nominal size, so it needs more room around the joint.

ISO-K internal weld flange — the tube welds in the bore and claw clamps close into the groove
ISO-K internal weld flange — the tube welds in the bore and claw clamps close into the groove
ISO-F looper flange — the bolted outer ring turns on the weld stub so the holes can be aligned after welding
ISO-F looper flange — the bolted outer ring turns on the weld stub so the holes can be aligned after welding
Aluminium bilateral C-type clamp — selected by bolt spec, with a recommended clamp count per flange size
Aluminium bilateral C-type clamp — selected by bolt spec, with a recommended clamp count per flange size

What the two letters actually change

The ISO letter describes the closure mechanism, not the seal. Read from the catalog side by side:

ISO-KISO-F
Flange styleInternal weld flange (tube welds in the bore)Looper / rotatable flange with a bolted outer ring
How it closesSingle-claw or bilateral claw calipers, or C-type clampsBolts through the outer ring
AlignmentClaws sit in the flange groove; the joint is indexed by the grooveThe outer ring turns on the weld stub, so the bolt pattern can be aligned after welding
Sealing hardwareCentering ring + O-ringCentering ring + O-ring (same set for the same size)
Catalog size rangeISO63 – ISO500ISO63 – ISO500
Typical useLines and ports where fast, hand-tooled access mattersInstrument interfaces, panels and confined installs where the joint must stay bolted and orientation-stable

Source: PC Vacuum catalog, ISO flange series (PC-027, PC-029). Size range is the catalog coverage; individual products may differ.

The important line in that table is the fourth one. A customer who has the right centering ring and O-ring for ISO100 has the right sealing set for either closure — the elastomer seat is not the decision. The decision is whether the joint will be opened with a clamp or held with bolts, and how much space the closure hardware is allowed to take.

Claws or bolts: the same centering ring and O-ring close the joint either way. The bolted ISO-F ring adds 35–60 mm of diameter for the same size
Claws or bolts: the same centering ring and O-ring close the joint either way. The bolted ISO-F ring adds 35–60 mm of diameter for the same size

The table that decides your layout

Here is the number that surprises people most often. Take the same nominal size and read the flange outer diameter, ∅A, from the two catalog tables:

Nominal sizeISO-K weld flange ∅AISO-F rotatable flange ∅AExtra diameter
ISO6395 mm130 mm+35 mm
ISO80110 mm145 mm+35 mm
ISO100130 mm165 mm+35 mm
ISO160180 mm225 mm+45 mm
ISO200240 mm285 mm+45 mm
ISO250290 mm335 mm+45 mm
ISO320370 mm425 mm+55 mm
ISO400450 mm510 mm+60 mm
ISO500550 mm610 mm+60 mm

Source: PC Vacuum catalog, PC-027 (ISO-K weld flange) and PC-029 (ISO-F rotatable flange). Diameters are catalog values; confirm against the drawing before order.

At ISO63 the bolted version is 35 mm wider across the flange; at ISO500 it is 60 mm. That is lost clearance on every side once the ring is in place — diameter grows on both sides of the axis. A joint that fits in a panel cut-out as ISO-K can fail to fit as ISO-F, and a bolt head or a socket still has to reach the ring when the flange is already 610 mm across.

This is why the ISO letter should be chosen together with the space around the joint, not after it. If the drawing is already tight, the ISO-K clamped closure is usually the smaller package; if the joint sits against a flat panel or a machined surface that must not move, the bolted ISO-F ring is the one that lets you align the holes after welding and then leave it fixed.

ISO-K: claw clamps, and how many

The ISO-K joint is closed by claws that engage the flange groove. The catalog carries three clamp families, and they are selected differently — two by flange size, one by bolt spec:

Flange sizeStainless claw caliper (PC-038)Aluminum single-claw (PC-039)Aluminum bilateral (PC-040)
ISO63 – ISO100M8 bolt, C 17–27 mm—M8 — four recommended
ISO160 – ISO250M10 bolt, C 27–35 mmM10 — six recommended (ISO160 – ISO200)M10 — six recommended (ISO100 – ISO200)
ISO320 – ISO500M12 bolt, C 35–45 mm—M12 — eight recommended (above ISO250)

Source: PC Vacuum catalog, clamp tables PC-038/PC-039/PC-040. Clamp counts are catalog recommendations — confirm the count for your assembly, since flange size, groove and working conditions all bear on it.

Two practical points from that table:

  • Match the clamp to the flange, not to the ISO number alone. The stainless claw calipers map one-to-one to flange sizes across the whole range. The aluminum C-type clamps are picked by bolt spec (M8 / M10 / M12) and then follow the recommended count — so the same “M10” clamp covers a span of sizes.
  • Clamps from the KF system do not fit ISO flanges. KF and ISO-K are different geometry; a KF clamp is not a smaller ISO clamp. See the KF fittings range if your small-bore section is KF.

Full clamp dimensions and the closing hardware are on the ISO vacuum clamps page; the flange side is on the ISO-K weld flange and ISO-K blank flange pages, within the wider ISO vacuum fittings range.

Stainless steel ISO claw caliper — selected by flange size, M8 / M10 / M12 bolt by size band
Stainless steel ISO claw caliper — selected by flange size, M8 / M10 / M12 bolt by size band
Aluminium bilateral C-type clamp — selected by bolt spec, with a recommended clamp count per flange size
Aluminium bilateral C-type clamp — selected by bolt spec, with a recommended clamp count per flange size

ISO-F: bolts, hole patterns and the rotating ring

ISO-F closes with bolts. The outer ring carries a drilled hole pattern, and the ring is free to turn on the weld stub — that rotation is the point of the design. You can weld the stub first, then rotate the ring so the holes line up with the mating flange or the equipment face. Fix the ring, run the bolts, and the joint holds a set orientation instead of relying on a clamp you may have to reach around.

The catalog hole patterns run as follows:

Nominal sizeISO-F hole patternISO-F ∅A
ISO634 × Φ9130 mm
ISO808 × Φ9145 mm
ISO1008 × Φ9165 mm
ISO1608 × Φ11225 mm
ISO20012 × Φ11285 mm
ISO25012 × Φ11335 mm
ISO32012 × Φ14425 mm
ISO40016 × Φ14510 mm
ISO50016 × Φ14610 mm

Source: PC Vacuum catalog, PC-029. Confirm hole pattern and bolt specification against the drawing and against your mating part before ordering.

The counts rise with size for a reason: a larger ring with the same number of bolts gives each bolt less of the ring to hold. Note that a 4-hole ISO63 and a 16-hole ISO500 are both “ISO-F” — the letter does not tell you the bolt count, so the hole pattern belongs on the drawing and in the enquiry.

Also worth stating plainly: bolt supply is confirmed at quotation. Specify the bolt spec and hole pattern requirements in the RFQ rather than assuming the fasteners come with the flange.

Installation space: where each closure wins

Put the two halves together and the choice becomes a short checklist:

  • Check the clearance first. ISO-F adds 35–60 mm of diameter over the ISO-K flange for the same size. If the joint sits inside a frame, a duct or a rack, run that number against the available gap before the drawing is frozen.
  • Check the tool path. Claw clamps need room to swing in and be tightened; bolts need room for a socket or spanner to reach each hole around the ring. Neither works if the surrounding structure blocks the tool, and the bolted ring is larger, so its tool circle is larger too.
  • Check whether the joint must stay put. If the mating face has a fixed orientation that has to be reproduced, the rotatable ISO-F ring lets you set the holes after welding and bolt it firm. If the joint will be opened often, the clamped ISO-K joint is quicker to break and re-make.
  • Check the environment. Whether the closure sits in a bake cycle, a vibration path or a clean area is a seal-and-material question, not a clamp-or-bolt question — but it is confirmed per application and should be stated, not assumed.
  • Check the accessories. Both closures use the same centering ring and O-ring for a given size, so ordering is by size, not by letter.

Can I mix ISO-K and ISO-F in one line?

Yes — within limits, and that is the usual reason the question comes up. A flange pair of the same nominal size uses the same centering ring and O-ring, so the seal is compatible; what you cannot do is close an ISO-K flange with the ISO-F ring, or vice versa. Where the two styles meet, the joint is closed one way or the other, chosen by which side needs the fast access and which needs the fixed orientation.

Where an ISO section has to join a KF or a CF section, that is a different part entirely — a cross-system adapter, not a different clamp. Those transitions change the bore and the sealing principle and are worth planning on purpose; see the flange adapters range.

For the wider picture of which system belongs where, the three-system comparison in KF vs ISO vs CF vacuum flanges sets ISO-K and ISO-F against the elastomer-sealed small-bore KF system and the metal-sealed CF system.

The checks to run before you send an enquiry

  1. State the closure explicitly. “ISO” alone is not enough — write ISO-K or ISO-F. A quotation cannot be built on an ambiguous letter.
  2. Give the nominal size and the flange outer diameter you must fit into, so the ØA difference is checked before the drawing is committed.
  3. For ISO-K: name the clamp family (stainless claw caliper, single-claw or bilateral aluminum) and the bolt spec your assembly can take. Confirm the recommended count.
  4. For ISO-F: give the hole pattern (n × Φ) and the bolt specification, plus the orientation requirement.
  5. Confirm the sealing set — centering ring and O-ring for the same nominal size, material chosen against the medium.
  6. Send the mating part or the equipment interface. The rotatable ring exists to align to something; the answer to “which way do the holes face” comes from the other side of the joint.
  7. Flag the working conditions — medium, working vacuum level, temperature, bake or clean requirements. These decide the elastomer and are confirmed per application.
  8. Attach the drawing. Every value above is a catalog value; the drawing is what gets made.

What to send with the enquiry

Send: closure (ISO-K or ISO-F) · nominal size(s) · flange outer diameter limit, if any · quantity · material · for ISO-K the clamp family and bolt spec, for ISO-F the hole pattern and bolt spec · O-ring material · medium and working vacuum level · mating flange or equipment interface · any bake, clean or orientation requirement · drawings.

Send your ISO sizes and drawings for a quotation

Frequently asked questions

What is the main difference between ISO-K and ISO-F?

The closure. Both use a centering ring and an O-ring between the faces; ISO-K closes with claw clamps, ISO-F with bolts through an outer ring. The ISO-F ring is larger in diameter than the ISO-K flange of the same size, so it needs more installation space.

Is ISO-F interchangeable with ISO-K?

The sealing hardware for a given nominal size is common, but the closure is not interchangeable — an ISO-K flange cannot take the ISO-F ring and vice versa. Components are matched by size and by closure type, not by the ISO letter alone.

Why is the ISO-F flange outer diameter larger?

The bolted outer ring adds material around the bore. In the catalog, ISO63 measures 95 mm as an ISO-K weld flange and 130 mm as an ISO-F rotatable flange; ISO500 measures 550 mm and 610 mm respectively. The gap widens with size because the ring has to carry more bolts.

How many clamps does an ISO-K flange need?

The catalog recommends four clamps (M8, ISO63–ISO100), six (M10, ISO100–ISO200 and single-claw ISO160–ISO200) and eight (M12, above ISO250). These are recommendations — confirm the count for your specific assembly.

Do ISO-K and ISO-F use the same O-ring and centering ring?

Yes, for the same nominal size. Order the sealing set by size; the choice of closure does not change it. O-ring material follows the medium, and its working temperature range is confirmed per application, not published as a general figure.

Can I use ISO-K clamps on a KF flange, or the other way round?

No. KF and ISO-K clamps are different geometry and are not interchangeable; match the clamp to the flange system first, then to the size.

Scroll to Top

Get a Quote