Quick answer. In our catalog the two options share the same valve body — same modular construction, same corrugated-tube shaft seal, same stainless steel body, forged and welded. What changes is the top end. The GD-J manual valve is driven by a screw: you turn the handle, the screw lifts the plate. The GDQ-J pneumatic valve replaces that hand input with an electromagnetic directional valve that steers compressed air to a cylinder, which drives the plate. So the decision is rarely “which seals better” — it is whether the line is operated by hand, whether compressed air and a solenoid supply exist at the installation, and whether the control system needs to know the valve position.



The choice in one table
| Manual (GD-J) | Pneumatic (GDQ-J) | |
|---|---|---|
| Actuation | Screw-driven by hand | Electromagnetic directional valve + air cylinder |
| Utilities required | None | Compressed air 0.4–0.6 MPa; solenoid supply |
| Power | — | AC220V 50Hz (AC110V or DC24V optional) |
| Position feedback | Visual (handle position) | Magnetic switch, optional |
| Installation direction | Any direction | ≤DN100 any direction; >DN100 vertical |
| Typical duty | Panel-mounted, hand-operated isolation | Remote, sequenced or interlocked operation |
| Working medium (catalog) | Air or low-corrosive gas | Air or low-corrosive gas |
The last two rows are the ones that decide most orders. A manual valve can be mounted in any orientation and asks for nothing from the site; a pneumatic valve asks for air and a solenoid supply, and above DN100 the catalog calls for vertical mounting.
What the actuator does not change
The connection to the vacuum line is a separate decision from the actuator. A valve built on KF ends closes over a centering ring and O-ring; a valve built on CF ends closes over a copper gasket against the knife edge; an ISO-K valve closes with claw clamps and the standard centering-ring set. Choosing manual or pneumatic does not move you between those systems — the flange family follows the line, not the actuator.
If the line itself is still open, start with the comparison of the three systems in KF vs ISO vs CF Vacuum Flanges; for large-bore clamped sections, ISO-K vs ISO-F covers the closure hardware and the space it needs.
Size coverage by connection
The two series do not cover the same range, and this is where many enquiries get resolved:
| Connection | Manual (GD-J) | Pneumatic (GDQ-J) | Catalog models |
|---|---|---|---|
| KF | KF16 – KF50 | KF16 – KF50 | GD-JB□□KF / GDQ-JB□□KF |
| CF | CF16 – CF50 | CF16 – CF250 | GD-JB□□CF / GDQ-JB□□CF |
| ISO-K | — | ISO63 – ISO320 | GDQ-JB□□(ISO-K) |
Two practical readings of that table. First, above CF50 the pneumatic series is the catalog’s cover for large CF valves — the manual CF table stops at CF50. Second, the ISO connection appears in the pneumatic series only; if you need a hand-operated ISO valve, that is a question for the quotation, not a catalog line.
The catalog KF and CF manual and pneumatic tables share the same bore and flange columns for a given size (A, B, C, L), so a KF25 line keeps its dimensions whether the valve is hand-driven or air-driven. What grows is the assembly height, because the cylinder sits on top — check the overall height for the actuated assembly against your layout before ordering.

Air supply, power and feedback
Three items have to exist at the installation before a pneumatic valve is specified:
- Compressed air at 0.4–0.6 MPa. This is the catalog air supply figure for the GDQ-J series. If the site has instrument air already, this is easy; if not, the compressor becomes part of the project.
- A solenoid supply, AC220V 50Hz as listed, with AC110V and DC24V available as options. State which one your control cabinet provides — this is a build option, not a field adjustment.
- Position indication, if the control system needs it. The pneumatic series offers an optional magnetic switch that indicates open/closed. If your sequence interlocks on valve position, order it; if a human reads the valve, the manual series needs no such option.
One catalog note worth catching early: a pumping port on the valve body is a special order — it is not standard equipment and has to be specified.
Installation direction: the rule people miss
The catalog states installation position as a series parameter, and it differs by actuation:
- Manual (GD-J): any direction. No restriction from the catalog.
- Pneumatic (GDQ-J): any direction up to DN100; vertical above DN100.
For ISO-K pneumatic valves this matters more than people expect, because the ISO range in the catalog starts at ISO63 and runs to ISO320 — most of it is above DN100, so vertical mounting is the working assumption, and the frame has to be designed for it.
Specifying the valve: the checklist
The actuator choice is one line. A complete specification resolves all of these, and most of them are the difference between a quotation and a second round of emails:
| # | Item | What to state |
|---|---|---|
| 1 | Connection system and size | KF / CF / ISO-K, and the size (e.g. KF25, CF63, ISO160) |
| 2 | Actuation | Manual (GD-J) or pneumatic (GDQ-J) |
| 3 | Medium | Air or low-corrosive gas per the catalog; state anything else |
| 4 | Working pressure / vacuum level | The duty the valve sees, not the catalog figure |
| 5 | Temperature duty | Confirmed per application — the seal material follows it |
| 6 | Leak-rate requirement | If the process has one, state it in the enquiry |
| 7 | Installation direction | Especially for >DN100 pneumatic valves |
| 8 | Air supply available (pneumatic) | Confirm it is within 0.4–0.6 MPa |
| 9 | Solenoid voltage | AC220V 50Hz, or the AC110V / DC24V option |
| 10 | Position feedback | Magnetic switch required or not |
| 11 | Pumping port | State it if you need one — special order |
| 12 | Cleaning and packaging | Per the receiving line’s requirement |
Items 1, 2 and 8–10 are the ones that change the quote; items 3–7 change whether the valve is the right one at all.
Which one for which job
Read the catalog ranges as they are used:
- Hand-operated isolation at a panel or chamber — pump isolation, branch shut-off, a line someone walks up to. The KF manual angle valve and CF manual angle valve cover KF16–KF50 and CF16–CF50 with no utilities attached.
- Remote or sequenced operation — interlocks, pump-down sequences, process control, anything the PLC drives. The pneumatic series covers KF, CF to CF250 and ISO-K to ISO320: see the KF pneumatic, CF pneumatic and ISO-K pneumatic pages.
- Rough-vacuum isolation where a quarter turn is enough — forelines and venting manifolds. The KF ball valve is a lever-operated isolation valve, not a high-vacuum baffle valve.
- Letting a line up to atmosphere — the vacuum vent valve is the manual venting component, on KF10–KF50 or as a weld-in version.
What we confirm per model, not on this page
Application range, leak rate and medium temperature limits are catalog parameters that we confirm against the model and the duty — they are not published here as generic figures. The same applies to actuation speed, fail position and control integration: those depend on the installation and the control scheme, so they belong in the enquiry. If your process carries a specific requirement, send it with the specification above and it is checked against the model.
What to send with the enquiry
Send the checklist table filled in as far as it goes, plus quantity and a drawing if the layout is constrained. Sizes and model codes are enough for a first quote when the duty is standard air or low-corrosive gas: a line like “GDQ-JB50KF, pneumatic, AC220V, with position indication, 4 off” is a complete starting point.
Frequently asked questions
Can a manual valve be converted to pneumatic later?
The pneumatic GDQ-J series covers automated duty as a separate model. Converting a manual body is not a catalog operation — it is confirmed at quotation.
What happens if the compressed air fails?
Fail position depends on the control scheme, not on the valve alone. Specify the required behaviour — fail open or fail closed — in the enquiry.
Do I need the magnetic position switch?
Only if the control system needs open/closed confirmation. It is an option on the pneumatic series; a hand-operated valve needs no feedback beyond the handle position.
Does a pneumatic valve still use a corrugated-tube shaft seal?
Yes — the shaft seal is the same construction across the GD-J and GDQ-J series; the actuator changes how the plate is driven, not how the stem is sealed.
Why does the catalog stop the manual CF valve at CF50?
The manual CF table lists CF16 to CF50. Larger CF sizes are covered by the pneumatic series, which runs to CF250.
Is the valve body all-metal sealed?
The CF connections close over copper gaskets, so the joint to the line is metal-sealed; the internal plate seal is a separate sealing element, and materials are confirmed for the duty.
What is the difference between “angle valve” and “baffle valve” on your pages?
Same product. The catalog prints “baffle valve” (挡板阀); the trade also says “angle valve” for the right-angle body. Our pages use the trade term.