Manual vs Pneumatic High-Vacuum Valves: How to Specify One

Quick answer. In our catalog the two options share the same valve body — same modular construction, same corrugated-tube shaft seal, same stainless steel body, forged and welded. What changes is the top end. The GD-J manual valve is driven by a screw: you turn the handle, the screw lifts the plate. The GDQ-J pneumatic valve replaces that hand input with an electromagnetic directional valve that steers compressed air to a cylinder, which drives the plate. So the decision is rarely “which seals better” — it is whether the line is operated by hand, whether compressed air and a solenoid supply exist at the installation, and whether the control system needs to know the valve position.

GD-J series manual KF high vacuum angle valve — screw-driven from the handwheel, no utilities required
GD-J series manual KF high vacuum angle valve — screw-driven from the handwheel, no utilities required
GDQ-J series pneumatic KF high vacuum angle valve — solenoid valve and air cylinder replace the handwheel
GDQ-J series pneumatic KF high vacuum angle valve — solenoid valve and air cylinder replace the handwheel
ISO-K pneumatic angle valve — the same cylinder package on the large-bore clamped connection, ISO63 to ISO320
ISO-K pneumatic angle valve — the same cylinder package on the large-bore clamped connection, ISO63 to ISO320

The choice in one table

Manual (GD-J)Pneumatic (GDQ-J)
ActuationScrew-driven by handElectromagnetic directional valve + air cylinder
Utilities requiredNoneCompressed air 0.4–0.6 MPa; solenoid supply
Power—AC220V 50Hz (AC110V or DC24V optional)
Position feedbackVisual (handle position)Magnetic switch, optional
Installation directionAny direction≤DN100 any direction; >DN100 vertical
Typical dutyPanel-mounted, hand-operated isolationRemote, sequenced or interlocked operation
Working medium (catalog)Air or low-corrosive gasAir or low-corrosive gas

The last two rows are the ones that decide most orders. A manual valve can be mounted in any orientation and asks for nothing from the site; a pneumatic valve asks for air and a solenoid supply, and above DN100 the catalog calls for vertical mounting.

What the actuator does not change

The connection to the vacuum line is a separate decision from the actuator. A valve built on KF ends closes over a centering ring and O-ring; a valve built on CF ends closes over a copper gasket against the knife edge; an ISO-K valve closes with claw clamps and the standard centering-ring set. Choosing manual or pneumatic does not move you between those systems — the flange family follows the line, not the actuator.

If the line itself is still open, start with the comparison of the three systems in KF vs ISO vs CF Vacuum Flanges; for large-bore clamped sections, ISO-K vs ISO-F covers the closure hardware and the space it needs.

Size coverage by connection

The two series do not cover the same range, and this is where many enquiries get resolved:

ConnectionManual (GD-J)Pneumatic (GDQ-J)Catalog models
KFKF16 – KF50KF16 – KF50GD-JB□□KF / GDQ-JB□□KF
CFCF16 – CF50CF16 – CF250GD-JB□□CF / GDQ-JB□□CF
ISO-K—ISO63 – ISO320GDQ-JB□□(ISO-K)

Two practical readings of that table. First, above CF50 the pneumatic series is the catalog’s cover for large CF valves — the manual CF table stops at CF50. Second, the ISO connection appears in the pneumatic series only; if you need a hand-operated ISO valve, that is a question for the quotation, not a catalog line.

The catalog KF and CF manual and pneumatic tables share the same bore and flange columns for a given size (A, B, C, L), so a KF25 line keeps its dimensions whether the valve is hand-driven or air-driven. What grows is the assembly height, because the cylinder sits on top — check the overall height for the actuated assembly against your layout before ordering.

Manual or pneumatic: the body, shaft seal and materials are common. The actuator decides utilities, mounting direction and position feedback
Manual or pneumatic: the body, shaft seal and materials are common. The actuator decides utilities, mounting direction and position feedback

Air supply, power and feedback

Three items have to exist at the installation before a pneumatic valve is specified:

  • Compressed air at 0.4–0.6 MPa. This is the catalog air supply figure for the GDQ-J series. If the site has instrument air already, this is easy; if not, the compressor becomes part of the project.
  • A solenoid supply, AC220V 50Hz as listed, with AC110V and DC24V available as options. State which one your control cabinet provides — this is a build option, not a field adjustment.
  • Position indication, if the control system needs it. The pneumatic series offers an optional magnetic switch that indicates open/closed. If your sequence interlocks on valve position, order it; if a human reads the valve, the manual series needs no such option.

One catalog note worth catching early: a pumping port on the valve body is a special order — it is not standard equipment and has to be specified.

Installation direction: the rule people miss

The catalog states installation position as a series parameter, and it differs by actuation:

  • Manual (GD-J): any direction. No restriction from the catalog.
  • Pneumatic (GDQ-J): any direction up to DN100; vertical above DN100.

For ISO-K pneumatic valves this matters more than people expect, because the ISO range in the catalog starts at ISO63 and runs to ISO320 — most of it is above DN100, so vertical mounting is the working assumption, and the frame has to be designed for it.

Specifying the valve: the checklist

The actuator choice is one line. A complete specification resolves all of these, and most of them are the difference between a quotation and a second round of emails:

#ItemWhat to state
1Connection system and sizeKF / CF / ISO-K, and the size (e.g. KF25, CF63, ISO160)
2ActuationManual (GD-J) or pneumatic (GDQ-J)
3MediumAir or low-corrosive gas per the catalog; state anything else
4Working pressure / vacuum levelThe duty the valve sees, not the catalog figure
5Temperature dutyConfirmed per application — the seal material follows it
6Leak-rate requirementIf the process has one, state it in the enquiry
7Installation directionEspecially for >DN100 pneumatic valves
8Air supply available (pneumatic)Confirm it is within 0.4–0.6 MPa
9Solenoid voltageAC220V 50Hz, or the AC110V / DC24V option
10Position feedbackMagnetic switch required or not
11Pumping portState it if you need one — special order
12Cleaning and packagingPer the receiving line’s requirement

Items 1, 2 and 8–10 are the ones that change the quote; items 3–7 change whether the valve is the right one at all.

Which one for which job

Read the catalog ranges as they are used:

  • Hand-operated isolation at a panel or chamber — pump isolation, branch shut-off, a line someone walks up to. The KF manual angle valve and CF manual angle valve cover KF16–KF50 and CF16–CF50 with no utilities attached.
  • Remote or sequenced operation — interlocks, pump-down sequences, process control, anything the PLC drives. The pneumatic series covers KF, CF to CF250 and ISO-K to ISO320: see the KF pneumatic, CF pneumatic and ISO-K pneumatic pages.
  • Rough-vacuum isolation where a quarter turn is enough — forelines and venting manifolds. The KF ball valve is a lever-operated isolation valve, not a high-vacuum baffle valve.
  • Letting a line up to atmosphere — the vacuum vent valve is the manual venting component, on KF10–KF50 or as a weld-in version.

What we confirm per model, not on this page

Application range, leak rate and medium temperature limits are catalog parameters that we confirm against the model and the duty — they are not published here as generic figures. The same applies to actuation speed, fail position and control integration: those depend on the installation and the control scheme, so they belong in the enquiry. If your process carries a specific requirement, send it with the specification above and it is checked against the model.

What to send with the enquiry

Send the checklist table filled in as far as it goes, plus quantity and a drawing if the layout is constrained. Sizes and model codes are enough for a first quote when the duty is standard air or low-corrosive gas: a line like “GDQ-JB50KF, pneumatic, AC220V, with position indication, 4 off” is a complete starting point.

Send your valve specification

Frequently asked questions

Can a manual valve be converted to pneumatic later?

The pneumatic GDQ-J series covers automated duty as a separate model. Converting a manual body is not a catalog operation — it is confirmed at quotation.

What happens if the compressed air fails?

Fail position depends on the control scheme, not on the valve alone. Specify the required behaviour — fail open or fail closed — in the enquiry.

Do I need the magnetic position switch?

Only if the control system needs open/closed confirmation. It is an option on the pneumatic series; a hand-operated valve needs no feedback beyond the handle position.

Does a pneumatic valve still use a corrugated-tube shaft seal?

Yes — the shaft seal is the same construction across the GD-J and GDQ-J series; the actuator changes how the plate is driven, not how the stem is sealed.

Why does the catalog stop the manual CF valve at CF50?

The manual CF table lists CF16 to CF50. Larger CF sizes are covered by the pneumatic series, which runs to CF250.

Is the valve body all-metal sealed?

The CF connections close over copper gaskets, so the joint to the line is metal-sealed; the internal plate seal is a separate sealing element, and materials are confirmed for the duty.

What is the difference between “angle valve” and “baffle valve” on your pages?

Same product. The catalog prints “baffle valve” (挡板阀); the trade also says “angle valve” for the right-angle body. Our pages use the trade term.

Scroll to Top