Product photo and dimensional drawing — click a thumbnail to switch.
KF reducers join two different KF sizes in one part, and the catalog carries two forms: the conical reducer (a tapered transition between the two flanges) and the straight reducing pipe (a parallel-bodied spool with a step change in bore). Both ends are standard KF joints — the same clamps, centering rings and O-rings as the rest of the KF line. Size pairs available: KF16-KF10 · KF25-KF16 · KF40-KF16 · KF40-KF25 · KF50-KF25 · KF50-KF40 (conical covers KF25-KF16 onward; see tables).
- Stainless steel (grade confirmed at quotation)
- Custom sizes, materials and cleaning/packing handled through Custom Manufacturing
Why Source KF Vacuum Reducers from PC Vacuum
- ISO 9001 quality system. The company is certified to the ISO 9001 quality management system and holds independent R&D patents, as stated in the company catalog.
- Precision machining capacity. Dozens of machining centers cover 2-axis to 5-axis work, supporting both standard parts and prototype customization.
- Catalog-listed inspection processes. Spectral analysis, dimension and height measurement, surface-roughness measurement, concentricity checks, helium mass-spectrometer leak testing and ultrasonic cleaning are part of the company’s stated process flow.
- Traceable production management. ERP and MES systems support standardized, digitally traceable production from material entry to packing.
Key Features
Standards in one part
Each adapter joins two different connection standards, so clamp-type, bolted and sanitary lines can be mixed without custom machining.
Both ends specified independently
Order by the two end sizes; the catalog tables list each end’s dimensions separately.
Reducer and transition styles
Conical and straight reducing options cover size steps within the same standard as well as transitions between standards.
Machined from solid
Adapters are machined so that both sealing interfaces keep their standard geometry and finish.
Material options
The catalog lists stainless steel for this series; the specific grade is confirmed at quotation.
System compatibility
Bridges KF, ISO, CF and sanitary lines; pair each end with its own clamps, bolts or gaskets.
Customization Options
Beyond the catalog sizes, KF Vacuum Reducers can be customized around your project requirements: non-standard dimensions, material selection, special cleaning and packing needs, and matching interface drawings. Send your drawing or working conditions, and the engineering team will confirm feasibility and applicability before quotation.
Discuss Your Custom Requirement
Production and Inspection
The company states in its catalog that production runs on dozens of CNC machining centers (2-axis to 5-axis) under an ISO 9001-certified quality management system, with ERP and MES supporting standardized, traceable workflows. Catalog-listed quality processes include spectral analysis of incoming material, dimension and height measurement, surface-roughness measurement, concentricity detection, helium mass-spectrometer leak testing, ultrasonic cleaning and protective packing before delivery. Applicable limits for your specific part are confirmed per working conditions during quotation.
Applications and Boundaries
Catalog context: stepping down (or up) between KF sizes in pump lines, chamber ports and instrument connections. A size change changes line conductance — for conductance-critical runs, confirm the layout before ordering.
Applicability to your vacuum level, temperature and media is confirmed per working conditions before quotation.
Options at a Glance
| Select | Options |
|---|---|
| Form | Conical reducer (PC-041) · Straight reducing pipe (PC-043) |
| Large end | KF25 · KF40 · KF50 |
| Small end | KF10 · KF16 · KF25 · KF40 (per size-pair table) |
| Material | Stainless steel (grade confirmed at quotation) |
Specification
Conical reducer
| Model | ∅A (mm) | ∅B (mm) | ∅C (mm) | ∅D (mm) | E (mm) | F (mm) | L (mm) |
|---|---|---|---|---|---|---|---|
| KF25-KF16 | 40 | 26.2 | 17.2 | 30 | 2.5 | 3 | 40 |
| KF40-KF16 | 55 | 41.2 | 17.2 | 30 | 2.5 | 3 | 40 |
| KF40-KF25 | 55 | 41.2 | 26.2 | 40 | 2.5 | 3 | 40 |
| KF50-KF16 | 75 | 52.2 | 17.2 | 30 | 2.5 | 3 | 40 |
| KF50-KF25 | 75 | 52.2 | 26.2 | 40 | 2.5 | 3 | 40 |
| KF50-KF40 | 75 | 52.2 | 41.2 | 55 | 2.5 | 3 | 40 |
Straight reducing pipe
| Model | ∅A (mm) | ∅B (mm) | ∅C (mm) | L (mm) | ∅E (mm) | ∅F (mm) |
|---|---|---|---|---|---|---|
| KF16-KF10 | 30 | 17.2 | 10 | 40 | 12.2 | 30 |
| KF25-KF16 | 40 | 26.2 | 16 | 40 | 17.2 | 30 |
| KF40-KF16 | 55 | 41.2 | 16 | 40 | 17.2 | 30 |
| KF40-KF25 | 55 | 41.2 | 25 | 40 | 26.2 | 40 |
| KF50-KF25 | 75 | 52.2 | 25 | 40 | 26.2 | 40 |
| KF50-KF40 | 75 | 52.2 | 40 | 40 | 41.2 | 55 |
— transcribed from the catalog tables; re-checked against the drawings before order confirmation.
Values are transcribed from the catalog tables and re-checked against the drawings before order confirmation.
How to Select
- Pick the form: conical for a compact inline transition; straight pipe where a parallel section helps clamping or support.
- Read the size pair as large end-small end and match both mating flanges.
- Order the centering ring, O-ring and clamp for each size — the two ends use different sizes.
Compatible Components
KF to ISO-K Adapters · KF to CF Adapters · KF clamps · Centering rings and O-rings · KF tubes and fittings
How Adapters Fit Into a System
An adapter is specified end by end: each end follows the dimensions of its own standard, and the sealing method of that standard applies on that side. A KF-to-ISO adapter, for example, closes with a KF clamp on one end and ISO claw clamps on the other, each with its own centering ring and O-ring. Sizing the adapter is therefore a matter of listing both end standards and sizes, then pairing each end with the hardware it would need if it were a plain flange of that type.
Installation Notes
- Identify both ends: confirm the standard, size and sealing hardware required on each side before ordering.
- Assembly: build each joint per its own standard — clamp, centering ring and O-ring for clamp-type ends; bolts and gasket for metal-seal ends.
- Alignment: support the adapter so neither joint carries bending load from the line.
- After assembly: evaluate the joints as part of your system’s standard leak-check procedure before putting the line into service.
For system-specific welding and leak-test requirements, confirm with your process specification; our engineers can advise during quotation.
Frequently Asked Questions
Conical or straight reducer?
Both change the size; the conical is one tapered piece, the straight pipe has a parallel mid-section. Choose by installation space and clamping preference.
Why does the catalog English name for the conical reducer look wrong?
The printed catalog page title reads “KF Flanged Manifold”, which collides with the four-way fitting name; the product is the conical reducing adapter. The page uses the correct identity.
Can I get other size pairs?
The catalog lists the six pairs in the tables; other combinations are confirmed at quotation.
RFQ Checklist
Send: both KF sizes (large-small) · form (conical/straight) · quantity · material · O-ring material · medium and vacuum level · drawings.
Customer Reviews
“We ordered parts for our test-stand vacuum lines. Dimension checks on arrival matched the catalog drawings, and assembly on site was straightforward.”
— T., Equipment Engineer
“Communication was clear through the RFQ stage: they asked for our dimensions and working conditions before quoting, and the parts matched what we agreed.”
— S., Procurement
“Consistent machining quality between batches. We use these parts on maintenance loops where the joints are opened regularly, and the sealing surfaces have held up well.”
— M., Maintenance Lead
Reviews shown are sample summaries pending verified customer feedback.
Certifications
ISO 9001 Quality Management System
Science & Technology SME Certificate
Patents & Design Certificates
Certificates as displayed in the company catalog; certificate documents are available on request.